Power, Power Factor & Wattless Current
In a series LR circuit, power of 400W is dissipated from a source of 250 V, 50 Hz. The power factor of the circuit is 0.8. In order to bring the power factor to unity, a capacitor of value C is added in series to the L and R. Taking the value of C as F, then value of n is __________.
Numerical answer type. Work it out, then open the answer.
Show answer
Answer: 400