Physics Circle home Student Login

Home›Chapters›Alternating Current PYQs›AC Generator & Transformer›Question 10

MHT CET 2026 (13 May, Shift 1) · AC Generator & Transformer

AC Generator & Transformer question from MHT CET 2026 (13 May, Shift 1)

Q10MHT CET 2026 · 13 MAY · SHIFT 1Medium

AC Generator & Transformer

A transformer having efficiency 90%90\% is working on 200200 V and 33 KW power supply. If the current in the secondary coil is 66A, the voltage across the secondary coil and the current in the primary coil, respectively, are

Show answer and solution

Answer: (b)

  1. Ip=3000200=15 AI_p = \dfrac{3000}{200} = 15\text{ A}
  2. Pout=0.9×3000=2700 WP_{out} = 0.9 \times 3000 = 2700\text{ W}
  3. Vs=27006=450 VV_s = \dfrac{2700}{6} = 450\text{ V}
  4. So the answer is (b) 450 V, 15 A.
Report a mistake

More questions on AC Generator & Transformer