For protecting a sensitive equipment from the external magnetic field, it should be

Show answer and solution

Answer: (b)

  1. Iron has very high permeability, so field lines are drawn into the iron walls and pass around the inside.
  2. The inside of an iron can is nearly field free. Aluminium and copper have μr≈1\mu_r \approx 1 and give no shielding.
  3. So the answer is (b) placed inside an iron can.