Electrical Power & Heating Effect

The thermo e.m.f. EE in volts of a certain thermo-couple is found to vary with temperature difference θ\theta in °C between the two junctions according to the relation

E=30θ−θ215E = 30\theta - \frac{\theta^2}{15}

The neutral temperature for the thermo-couple will be

Show answer and solution

Answer: (c)

  1. At neutral temperature dEdθ=0\frac{dE}{d\theta} = 0.
  2. 30−2θ15=0⇒θ=225∘30 - \frac{2\theta}{15} = 0 \Rightarrow \theta = 225^\circC
  3. So the answer is (c).