Q1MHT CET 2026 · 13 MAY · SHIFT 2Easy

AC Generator & Transformer

A step down transformer has 5050 turns on secondary and 10001000 turns on primary winding. If a transformer is connected to 220220 V and 11 A a.c. source, what is the output current of the transformer?

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q2MHT CET 2026 · 17 APR · SHIFT 1Easy

AC Generator & Transformer

A transformer has 120 turns in the primary coil and carries 5A current. Input power is one kilowatt. To have 560 V output, the number of turns in secondary coil will be

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q3MHT CET 2026 · 16 APR · SHIFT 1Easy

AC Generator & Transformer

A step down transformer has turns ratio 20:1. If 8V are applied across 0.4 Ω0.4\ \Omega secondary then the primary current will be

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q4MHT CET 2026 · 11 APR · SHIFT 2Easy

AC Generator & Transformer

An ideal transformer converts 220220V a.c. to 3.33.3 KV a.c. to transmit a power of 4.44.4 KW. If primary coil has 600600 turns then alternating current in the secondary coil is

Show answer and solution

Answer: (a)

Loading the solution…
Report a mistakeOpen question page
Q5MHT CET 2026 · 19 MAY · SHIFT 2Medium

AC Generator & Transformer

The output of step-down transformer is measured to be 3636 V when connected to 66 W light bulb. The value of peak current is

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q6MHT CET 2026 · 15 MAY · SHIFT 1Medium

AC Generator & Transformer

If a transformer of an amplifier has output impedance 8000 Ω8000\ \Omega and the speaker has input impedance of 8 Ω8\ \Omega, the primary and secondary turns of this transformer connected between the output of amplifier and to loudspeaker should have the ratio

Show answer and solution

Answer: (d)

Loading the solution…
Report a mistakeOpen question page
Q7MHT CET 2026 · 16 APR · SHIFT 2Medium

AC Generator & Transformer

Alternating current of peak value (2π)\left(\frac{2}{\pi}\right) A flows through the primary coil of a transformer. The coefficient of mutual inductance between primary and secondary coils is 1H. The peak value of induced e.m.f. in the secondary coil is

(Frequency of a.c. = 50 Hz)

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q8MHT CET 2026 · 19 MAY · SHIFT 1Medium

AC Generator & Transformer

A transformer having an efficiency 80% is working on 200200 V and 44 kW power supply. If the current in the secondary coil is 55 A, the voltage across the secondary coil and the current in the primary coil, respectively, are

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q9MHT CET 2026 · 14 MAY · SHIFT 2Medium

AC Generator & Transformer

A current of 55 A is flowing at 220220 V in the primary coil of a transformer. If the voltage produced in the secondary coil is 22002200 V and 50%50\% of power is lost, then the current in secondary will be

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q10MHT CET 2026 · 13 MAY · SHIFT 1Medium

AC Generator & Transformer

A transformer having efficiency 90%90\% is working on 200200 V and 33 KW power supply. If the current in the secondary coil is 66A, the voltage across the secondary coil and the current in the primary coil, respectively, are

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q11MHT CET 2026 · 20 APR · SHIFT 2Medium

AC Generator & Transformer

A current of 4 A is flowing at 230 V in the primary coil of a transformer. If the voltage produced in the secondary coil is 2300 V and 40 % of power is lost, then the current in the secondary will be

Show answer and solution

Answer: (a)

Loading the solution…
Report a mistakeOpen question page
Q12MHT CET 2025 · 20 APR · SHIFT 2Easy

AC Generator & Transformer

An ideal transformer converts 220 a.c. to 3.3 kV a.c. to transmit a power of 4.4 kW. If primary coil has 600 turns then alternating current in secondary coil is

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q13MHT CET 2025 · 23 APR · SHIFT 1Easy

AC Generator & Transformer

A current of 5 A is flowing at 220 V in a primary coil of a transformer. If the voltage produced in the secondary coil is 2200 V and 50%50\% of power is lost, then the current in the secondary coil will be

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q14MHT CET 2024 · 10 MAY · SHIFT 2Easy

AC Generator & Transformer

A transformer has 120 turns in the primary coil and carries 5 A current. Input power is one kilowatt. To have 560 V output, the number of turns in secondary coil will be

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q15MHT CET 2024 · 3 MAY · SHIFT 2Easy

AC Generator & Transformer

A transformer is used to set up an alternating e.m.f. of 220 V to 4.4 kV to transmit 6.6 kW of power. The primary coil has 1000 turns. The current rating of the secondary coil is (Transformer is ideal)

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q16NEET 2024Easy

AC Generator & Transformer

A step up transformer is connected to an ac mains supply of 220 V220\text{ V} to operate at 11000 V, 8811000\text{ V},\ 88 watt. The current in the secondary circuit, ignoring the power loss in the transformer, is

Show answer and solution

Answer: (a)

Loading the solution…
Report a mistakeOpen question page
Q17NEET 2024Easy

AC Generator & Transformer

In an ideal transformer, the turns ratio is NPNS=12\frac{N_P}{N_S} = \frac{1}{2}. The ratio VS:VPV_S : V_P is equal to (the symbols carry their usual meaning):

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q18JEE Main 2024 · 30 JAN · SHIFT 1Easy

AC Generator & Transformer

Primary coil of a transformer is connected to 220 V220\text{ V} ac. Primary and secondary turns of the transformer are 100 and 10 respectively. Secondary coil of transformer is connected to two series resistances shown in figure. The output voltage (V0)(V_0) is:

Figure

Show answer and solution

Answer: (a)

Loading the solution…
Report a mistakeOpen question page
Q19MHT CET 2024 · 15 MAY · SHIFT 2Easy

AC Generator & Transformer

The core used in transformers are laminated to

Show answer and solution

Answer: (d)

Loading the solution…
Report a mistakeOpen question page
Q20MHT CET 2024 · 2 MAY · SHIFT 2Easy

AC Generator & Transformer

The core used in transformer and other electromagnetic devices is laminated to

Show answer and solution

Answer: (d)

Loading the solution…
Report a mistakeOpen question page
Q21JEE Main 2024 · 1 FEB · SHIFT 2Easy

AC Generator & Transformer

A transformer has an efficiency of 80%80\% and works at 10 V10\text{ V} and 4 kW4\text{ kW}. If the secondary voltage is 240 V240\text{ V}, then the current in the secondary coil is:

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q22MHT CET 2024 · 16 MAY · SHIFT 2Medium

AC Generator & Transformer

If a transformer of an audio amplifier has output impedance 8000 Ω8000\,\Omega and the speaker has input impedance 8 Ω8\,\Omega, the primary and secondary turns of this transformer connected between the output of amplifier and to loudspeaker should have the ratio

Show answer and solution

Answer: (d)

Loading the solution…
Report a mistakeOpen question page
Q23MHT CET 2024 · 15 MAY · SHIFT 1Medium

AC Generator & Transformer

Alternating current of peak value (2π)\left(\frac{2}{\pi}\right) A flows through the primary coil of a transformer. The coefficient of mutual inductance between primary and secondary coils is 1 H. The peak e.m.f. induced in secondary coil (Frequency of a.c. =50 Hz= 50\text{ Hz})

Show answer and solution

Answer: (d)

Loading the solution…
Report a mistakeOpen question page
Q24JEE Main 2024 · 27 JAN · SHIFT 2Medium

AC Generator & Transformer

Primary side of a transformer is connected to 230 V, 50 Hz230\text{ V},\ 50\text{ Hz} supply. Turns ratio of primary to secondary winding is 10:110 : 1. Load resistance connected to secondary side is 46 Ω46\,\Omega. The power consumed in it is:

Show answer and solution

Answer: (a)

Loading the solution…
Report a mistakeOpen question page
Q25MHT CET 2024 · 3 MAY · SHIFT 1Medium

AC Generator & Transformer

A transformer having efficiency 90%90\% is working on 200 V and 3 kw power supply. If the current in the secondary coil is 6 A, the voltage across the secondary coil and the current in the primary coil are respectively

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q26JEE Main 2024 · 30 JAN · SHIFT 2Difficult

AC Generator & Transformer

A power transmission line feeds input power at 2.3 kV2.3\text{ kV} to a step down transformer with its primary winding having 3000 turns. The output power is delivered at 230 V230\text{ V} by the transformer. The current in the primary of the transformer is 5 A5\text{ A} and its efficiency is 90%90\%. The winding of transformer is made of copper. The output current of transformer is _________ AA.

Numerical answer type. Work it out, then open the answer.

Show answer and solution

Answer: 45

Loading the solution…
Report a mistakeOpen question page
Q27MHT CET 2023 · 9 MAY · SHIFT 1Easy

AC Generator & Transformer

The coil of an a.c. generator has 100 turns, each of cross-sectional area 2 m22\text{ m}^2. It is rotating at constant angular speed 30 rad/s30\text{ rad/s}, in a uniform magnetic field of 2×10−2 T2 \times 10^{-2}\text{ T}. If the total resistance of the circuit is 600 Ω600\ \Omega then maximum power dissipated in the circuit is

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q28JEE Main 2023 · 1 FEB · SHIFT 1Easy

AC Generator & Transformer

Match List - I with List - II:

Choose the correct answer from the options given below:

List IList II
A.AC generatorI.Presence of both L and C
B.TransformerII.Electromagnetic Induction
C.Resonance phenomenon to occurIII.Quality factor
D.Sharpness of resonanceIV.Mutual Induction
Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q29JEE Main 2023 · 30 JAN · SHIFT 2Easy

AC Generator & Transformer

In an ac generator, a rectangular coil of 100 turns each having area 14×10−2 m214 \times 10^{-2}\text{ m}^2 is rotated at 360 rev/min360\text{ rev/min} about an axis perpendicular to a uniform magnetic field of magnitude 3.0 T3.0\text{ T}. The maximum value of the emf produced will be ________ VV.

(( Take π=227)\pi = \frac{22}{7})

Numerical answer type. Work it out, then open the answer.

Show answer and solution

Answer: 1584

Loading the solution…
Report a mistakeOpen question page
Q30MHT CET 2023 · 13 MAY · SHIFT 2Easy

AC Generator & Transformer

The number of turns in the primary and the secondary of a transformer are 1000 and 3000, respectively. If 80 V AC80\text{ V AC} is applied to the primary coil of the transformer, then the potential difference per turn of the secondary coil would be

Show answer and solution

Answer: (d)

Loading the solution…
Report a mistakeOpen question page
Q31NEET 2023Easy

AC Generator & Transformer

A 12 V, 60 W12\text{ V},\ 60\text{ W} lamp is connected to the secondary of a step down transformer, whose primary is connected to ac mains of 220 V220\text{ V}. Assuming the transformer to be ideal, what is the current in the primary winding?

Show answer and solution

Answer: (d)

Loading the solution…
Report a mistakeOpen question page
Q32JEE Main 2023 · 1 FEB · SHIFT 2Medium

AC Generator & Transformer

A square shaped coil of area 70 cm270\text{ cm}^2 having 600 turns rotates in a magnetic field of 0.4 wbm−20.4\text{ wbm}^{-2}, about an axis which is parallel to one of the sides of the coil and perpendicular to the direction of field. If the coil completes 500 revolutions in a minute, the instantaneous emf when the plane of the coil is inclined at 60∘60^\circ with the field, will be ____________ V. (Take π=227\pi = \frac{22}{7})

Numerical answer type. Work it out, then open the answer.

Show answer and solution

Answer: 44

Loading the solution…
Report a mistakeOpen question page
Q33JEE Main 2023 · 6 APR · SHIFT 1Difficult

AC Generator & Transformer

An ideal transformer with purely resistive load operates at 12 kV12\text{ kV} on the primary side. It supplies electrical energy to a number of nearby houses at 120 V120\text{ V}. The average rate of energy consumption in the houses served by the transformer is 60 kW\text{kW}. The value of resistive load (Rs)(\text{Rs}) required in the secondary circuit will be ___________ mΩ\text{m}\Omega.

Numerical answer type. Work it out, then open the answer.

Show answer and solution

Answer: 240

Loading the solution…
Report a mistakeOpen question page
Q34JEE Main 2022 · 25 JUN · SHIFT 1Easy

AC Generator & Transformer

Match List-I with List-II.

Choose the correct answer from the options given below:

List - IList -II
(A)AC generator(I)Detects the presence of current in the circuit
(B)Galvanometer(II)Converts mechanical energy into electrical energy
(C)Transformer(III)Works on the principle of resonance in AC circuit
(D)Metal detector(IV)Changes an alternating voltage for smaller or greater value
Show answer and solution

Answer: (a)

Loading the solution…
Report a mistakeOpen question page
Q35JEE Main 2022 · 28 JUL · SHIFT 2Medium

AC Generator & Transformer

A transformer operating at primary voltage 8 kV8\text{ kV} and secondary voltage 160 V160\text{ V} serves a load of 80 kW80\text{ kW}. Assuming the transformer to be ideal with purely resistive load and working on unity power factor, the loads in the primary and secondary circuit would be

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q36JEE Main 2021 · 25 FEB · SHIFT 2Easy

AC Generator & Transformer

Match List I with List II.

Choose the correct answer from the options given below:

List IList II
(a)Rectifier(i)Used either for stepping up or stepping down the a.c. voltage
(b)Stabilizer(ii)Used to convert a.c. voltage into d.c. voltage
(c)Transformer(iii)Used to remove any ripple in the rectified output voltage
(d)Filter(iv)Used for constant output voltage even when the input voltage or load current change
Show answer and solution

Answer: (a)

Loading the solution…
Report a mistakeOpen question page
Q37MHT CET 2021 · 24 SEP · SHIFT 1Easy

AC Generator & Transformer

A step up transformer operates on 220 V220\text{ V} and supplies current of 2 A2\text{ A}. The ratio of primary and secondary windings is 1:201 : 20. The current in the primary is

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q38MHT CET 2021 · 22 SEP · SHIFT 2Easy

AC Generator & Transformer

A step down transformer has turns ratio 20:120 : 1. If 8 V8\text{ V} is applied across 0.4 ohm0.4\text{ ohm} secondary then the primary current will be

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q39MHT CET 2021 · 21 SEP · SHIFT 2Easy

AC Generator & Transformer

In a step up transformer, which one of the following statements is correct?

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q40MHT CET 2021 · 20 SEP · SHIFT 2Easy

AC Generator & Transformer

In an ideal step down transformer, out of the following quantities, which quantity increases in the secondary coil?

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q41NEET 2021Easy

AC Generator & Transformer

A step down transformer connected to an ac mains supply of 220 V is made to operate at 11 V, 44W lamp. Ignoring power losses in the transformer, what is the current in the primary circuit?

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q42JEE Main 2021 · 16 MAR · SHIFT 2Easy

AC Generator & Transformer

For the given circuit, comment on the type of transformer used.

Figure

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q43MHT CET 2021 · 22 SEP · SHIFT 2Medium

AC Generator & Transformer

A step down transformer is used to reduce the main supply from 'V1V_1 ' volt to 'V2V_2 ' volt. The primary coil draws a current 'I1I_1' A\text{A} and the secondary coil draws 'I2I_2 ' A. (I1<I2)(I_1 < I_2). The ratio of input power to output power is

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q44JEE Main 2021 · 24 FEB · SHIFT 1Difficult

AC Generator & Transformer

A common transistor radio set requires 12 V (D.C.) for its operation. The D.C. source is constructed by using a transformer and a rectifier circuit, which are operated at 220 V (A.C.) on standard domestic A.C. supply. The number of turns of secondary coil are 24, then the number of turns of primary are ___________.

Numerical answer type. Work it out, then open the answer.

Show answer and solution

Answer: 440

Loading the solution…
Report a mistakeOpen question page
Q45MHT CET 2020 · 16 OCT · SHIFT 2Easy

AC Generator & Transformer

A step-up transformer has 300 turns of primary winding and 450 turns of secondary winding. A primary is connected to 150 V and the current flowing through it is 9A. The current and voltage in the secondary are

Show answer and solution

Answer: (d)

Loading the solution…
Report a mistakeOpen question page
Q46MHT CET 2019 · 3 MAY · SHIFT 1Easy

AC Generator & Transformer

A 220 V input is supplied to a transformer. The output circuit draws a current of 2.0 A at 440 V. If the ratio of output to input power is 0.8, then the current drawn by primary winding is

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q47JEE Main 2019 · 10 APR · SHIFT 1Easy

AC Generator & Transformer

A transformer consisting of 300 turns in the primary and 150 turns in the secondary gives output power of 2.2 kW. If the current in the secondary coil is 10A, then the input voltage and current in the primary coil are:

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q48JEE Main 2019 · 9 JAN · SHIFT 2Medium

AC Generator & Transformer

A power transmission line feeds input power at 2300 V to a step down transformer with its primary windings having 4000 turns. The output power is delivered at 230 V by the transformer. If the current in the primary of the transformer is 5A and its efficiency is 90%, the output current would be:

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q49JEE Main 2018 · 16 APR · SHIFT 1Easy

AC Generator & Transformer

A power transmission line feeds input power at 2300 V to a step down transformer with its primary windings having 4000 turns, giving the output power at 230 V. If the current in the primary of the transformer is 5 A, and its efficiency is 90%, the output current would be;

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q50NEET 2014 · AIPMTEasy

AC Generator & Transformer

A transformer having efficiency of 90% is working on 200 V and 3 kW power supply. If the current in the secondary coil is 6 A, the voltage across the secondary coil and the current in the primary coil respectively are

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q51NEET 2013Easy

AC Generator & Transformer

The primary of a transformer when connected to a dc battery of 10 Volt draws a current of 1 mA. The number of turns of the primary and secondary windings are 50 and 100 respectively. The voltage in the secondary and the current drawn by the circuit in the secondary are respectively

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q52NEET 2010 · AIPMT · PRELIMSEasy

AC Generator & Transformer

A 220 volt input is supplied to a transformer. The output circuit draws a current of 2.0 ampere at 440 volts. If the efficiency of the transformer is 80%, the current drwn by the primary windings of the transformer is

Show answer and solution

Answer: (d)

Loading the solution…
Report a mistakeOpen question page
Q53NEET 2007 · AIPMTEasy

AC Generator & Transformer

A transformer is used to light a 100 W and 110 V lamp from a 220 V mains. If the main current is 0.5 amp, the efficiency of the transformer is approximately

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q54NEET 2007 · AIPMTMedium

AC Generator & Transformer

The primary and secondary coils of a transformer have 50 and 1500 turns respectively. If the magnetic flux ϕ\phi linked with the primary coil is given by ϕ=ϕ\phi = \phi0 + 4t, where ϕ\phi is webers, t is time in seconds and ϕ\phi0 is a constant, the output voltage across the secondary coil is

Show answer and solution

Answer: (a)

Loading the solution…
Report a mistakeOpen question page
Q55JEE Main 2006 · AIEEEEasy

AC Generator & Transformer

In an ACAC generator, a coil with NN turns, all of the same area AA and total resistance R,R, rotates with frequency ω\omega in a magnetic field B.B. The maximum value of emfemf generated in the coil is

Show answer and solution

Answer: (d)

Loading the solution…
Report a mistakeOpen question page
Q56NEET 2006 · AIPMTEasy

AC Generator & Transformer

The core of a transformer is laminated because

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q57JEE Main 2003 · AIEEEEasy

AC Generator & Transformer

The core of any transformer is laminated so as to

Show answer and solution

Answer: (a)

Loading the solution…
Report a mistakeOpen question page
Q58JEE Main 2002 · AIEEEEasy

AC Generator & Transformer

In a transformer, number of turns in the primary coil are 140140 and that in the secondary coil are 280.280. If current in primary coil is 4A,4A, then that in the secondary coil is

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q59NEET 1998 · AIPMTEasy

AC Generator & Transformer

A step-up transformer operates on a 230 V230\text{ V} line and supplies current of 2 A2\text{ A} to a load. The ratio of the primary and secondary windings is 1:251 : 25. The current in the primary coil is

Show answer and solution

Answer: (b)

Loading the solution…
Report a mistakeOpen question page
Q60NEET 1997 · AIPMTEasy

AC Generator & Transformer

The primary winding of a transformer has 500 turns whereas its secondary has 5000 turns. The primary is connected to an A.C. supply 20 V, 50 Hz. The secondary will have an output of

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q61NEET 1988 · AIPMTMedium

AC Generator & Transformer

In a region of magnetic induction B=10−2B = 10^{-2} tesla, a circular coil of radius 30 cm and resistance π2\pi^2 ohm is rotated about an axis which is perpendicular to the direction of BB and which forms a diameter of the coil. If the coil rotates at 200 rpm the amplitude of the alternating current induced in the coil is

Show answer and solution

Answer: (c)

Loading the solution…
Report a mistakeOpen question page
Q62NDA 2023Easy

AC Generator & Transformer

Ms. Rani decides to convert her AC generator into a DC generator. Which one of the following she would need to use?

Show answer

Answer: (a)

Step-by-step solution coming soon.

Report a mistake
Q63NDA 2017Easy

AC Generator & Transformer

Step-up transformers are used for

Show answer

Answer: (d)

Step-by-step solution coming soon.

Report a mistake
Q64NDA 2017Easy

AC Generator & Transformer

Which one of the following devices changes low voltage alternating current to high voltage alternating current and vice versa?

Show answer

Answer: (c)

Step-by-step solution coming soon.

Report a mistake
Q65JEE Advanced 2013Medium

AC Generator & Transformer

A thermal power plant produces electric power of 600 kW600\,\text{kW} at 4000 V4000\,\text{V}, which is to be transported to a place 20 km20\,\text{km} away from the power plant for consumers' usage. It can be transported either directly with a cable of large current carrying capacity or by using a combination of step-up and step-down transformers at the two ends. The drawback of the direct transmission is the large energy dissipation. In the method using transformers, the dissipation is much smaller. In this method, a step-up transformer is used at the plant side so that the current is reduced to a smaller value. At the consumers' end, a step-down transformer is used to supply power to the consumers at the specified lower voltage. It is reasonable to assume that the power cable is purely resistive and the transformers are ideal with power factor unity. All the currents and voltages mentioned are rms values.

In the method using the transformers, assume that the ratio of the number of turns in the primary to that in the secondary in the step-up transformer is 1:101:10. If the power of the consumers has to be supplied at 200 V200\,\text{V}, the ratio of the number of turns in the primary to that in the secondary in the step-down transformer is

Show answer

Answer: (a)

Step-by-step solution coming soon.

Report a mistake
Q66JEE Advanced 2007Medium

AC Generator & Transformer

STATEMENT 1

A vertical iron rod has a coil of wire wound over it at the bottom end. An alternating current flows in the coil. The rod goes through a conducting ring as shown in the figure. The ring can float at a certain height above the coil.

Because

STATEMENT 2

In the above situation, a current is induced in the ring which interacts with the horizontal component of the magnetic field to produce an average force in the upward direction.

Vertical iron rod with a coil wound at its bottom and a conducting ring floating around the rod above the coil
Show answer

Answer: (a)

Step-by-step solution coming soon.

Report a mistake
Q67AIIMS 2019Medium

AC Generator & Transformer

A transformer with turns ratio N1N2=501\dfrac{N_1}{N_2} = \dfrac{50}{1} is connected to a 120 V120\,\text{V} AC supply. If primary and secondary circuit resistances are 1.5 kΩ1.5\,\text{k}\Omega and 1 Ω1\,\Omega respectively, then find out power of output.

Show answer

Answer: (a)

Step-by-step solution coming soon.

Report a mistake
Q68AIIMS 2012Easy

AC Generator & Transformer

A transformer of 100%100\% efficiency has 200 turns in the primary coil and 40000 turns in secondary coil. It is connected to a 220 V220\,\text{V} main supply and secondary feeds to a 100 kΩ100\,\text{k}\Omega resistance. The potential difference per turn is

Show answer

Answer: (a)

Step-by-step solution coming soon.

Report a mistake
Q69AIIMS 2012Easy

AC Generator & Transformer

A step down transformer is used on a 1000 V1000\,\text{V} line to deliver 20 A20\,\text{A} at 120 V120\,\text{V} at the secondary coil. If the efficiency of the transformer is 80%80\%, the current drawn from the line is

Show answer

Answer: (a)

Step-by-step solution coming soon.

Report a mistake
Q70AIIMS 2010Easy

AC Generator & Transformer

Assertion: A transformer cannot work on DC supply.
Reason: DC changes neither in magnitude nor in direction.

Show answer

Answer: (a)

Step-by-step solution coming soon.

Report a mistake
Q71AIIMS 2007Easy

AC Generator & Transformer

A six pole generator with fixed field excitation developes an emf of 100 V100\,\text{V}, when operating at 1500 rpm1500\,\text{rpm}. At what speed must it rotate to develop 120 V120\,\text{V}?

Show answer

Answer: (b)

Step-by-step solution coming soon.

Report a mistake
Q72AIIMS 2007Medium

AC Generator & Transformer

The primary and secondary coils of a transformer have 50 and 1500 turns respectively. If the magnetic flux ϕ\phi linked with the primary coil is given by ϕ=ϕ0+4t\phi = \phi_0 + 4t, where ϕ\phi is in weber, tt is time in second and ϕ0\phi_0 is a constant, the output voltage across the secondary coil is

Show answer

Answer: (b)

Step-by-step solution coming soon.

Report a mistake
Q73JIPMER 2016Medium

AC Generator & Transformer

A transformer having efficiency of 75%75\% is working on 220 V220\,\text{V} and 4.4 kW4.4\,\text{kW} power supply. If the current in the secondary coil is 5 A5\,\text{A}. What will be the voltage across secondary coil and the current in primary coil?

Show answer

Answer: (c)

Step-by-step solution coming soon.

Report a mistake
Q74JIPMER 2011Easy

AC Generator & Transformer

Voltage in the secondary coil of a transformer does not depend upon

Show answer

Answer: (a)

Step-by-step solution coming soon.

Report a mistake
Q75JIPMER 2009Easy

AC Generator & Transformer

A transformer is used to light a 100 W100\,\text{W} and 110 V110\,\text{V} lamp from a 220 V220\,\text{V} mains. If the main current is 0.5 A0.5\,\text{A}, the efficiency of the transformer is approximately

Show answer

Answer: (c)

Step-by-step solution coming soon.

Report a mistake
Q76JIPMER 2009Medium

AC Generator & Transformer

The primary and secondary coils of a transformer have 5050 and 15001500 turns respectively. If the magnetic flux ϕ\phi linked with the primary coil is given by ϕ=ϕ0+4t\phi = \phi_0 + 4t, where ϕ\phi is in weber, tt is time in second and ϕ0\phi_0 is a constant, the output voltage across the secondary coil is

Show answer

Answer: (b)

Step-by-step solution coming soon.

Report a mistake
Q77JIPMER 2008Easy

AC Generator & Transformer

When power is drawn from the secondary coil of the transformer, the dynamic resistance

Show answer

Answer: (a)

Step-by-step solution coming soon.

Report a mistake
Q78VITEEE 2024Easy

AC Generator & Transformer

A transformer has 200200 windings in the primary and 400400 windings in the secondary. The primary is connected to an AC supply of 110 V110\,\text{V} and a current of 10 A10\,\text{A} flows in it. The voltage across the secondary and the current in it, respectively, are

Show answer

Answer: (d)

Step-by-step solution coming soon.

Report a mistake
Q79VITEEE 2024Medium

AC Generator & Transformer

The primary of a transformer has 400400 turns while the secondary has 20002000 turns. If the power output from the secondary at 1000 V1000\,\text{V} is 12 kW12\,\text{kW}. The resistance of the primary is 0.2 Ω0.2\,\Omega and that of the secondary is 2 Ω2\,\Omega. If the efficiency of the transformer is 80%80\%, then the power loss in the primary is

Show answer

Answer: (b)

Step-by-step solution coming soon.

Report a mistake
Q80VITEEE 2012Easy

AC Generator & Transformer

The turn ratio of transformers is given as 2:32:3. If the current through the primary coil is 3 A3\,\text{A}, thus calculate the current through load resistance

Show answer

Answer: (c)

Step-by-step solution coming soon.

Report a mistake
Q81VITEEE 2011Easy

AC Generator & Transformer

The output voltage of a transformer connected to 220 V220\,\text{V} line is 1100 V1100\,\text{V} at 2 A2\,\text{A} current. Its efficiency is 100%100\%. The current coming from the line is

Show answer

Answer: (b)

Step-by-step solution coming soon.

Report a mistake
Q82VITEEE 2008Easy

AC Generator & Transformer

A transformer rated at 10 kW10\,\text{kW} is used to connect a 5 kV5\,\text{kV} transmission line to a 240 V240\,\text{V} circuit. The ratio of turns in the windings of the transformer is

Show answer

Answer: (b)

Step-by-step solution coming soon.

Report a mistake
Q83VITEEE 2007Easy

AC Generator & Transformer

A rectangular coil ABCDABCD which is rotated at a constant angular velocity about an horizontal as shown in the figure. The axis of rotation of the coil as well as the magnetic field BB are horizontal. Maximum current will flow in the circuit when the plane of the coil is

Rectangular coil ABCD rotating about a horizontal axis in a horizontal uniform magnetic field
Show answer

Answer: (d)

Step-by-step solution coming soon.

Report a mistake
Q84COMEDK 2026Medium

AC Generator & Transformer

An AC generator having 400400 turns and an area of cross section of 2×10−3 m22 \times 10^{-3}\,\text{m}^2 rotates with an angular speed of 200π rad s−1200\pi\,\text{rad s}^{-1} in a uniform magnetic field of strength 0.4 T0.4\,\text{T}. The generator is connected to the primary of an ideal transformer having 500500 turns in the primary and 20002000 turns in the secondary. The secondary is connected to a 400 Ω400\,\Omega resistive load. What is the rms current in the secondary of the transformer? Assume, the transformer is ideal and the resistance of the coil is negligible

Show answer

Answer: (c)

Step-by-step solution coming soon.

Report a mistake
Q85COMEDK 2025Medium

AC Generator & Transformer

A power transmission line feeds input power at 2200 V2200\,\text{V} to a step-down transformer with its primary windings having 20002000 turns. The output power is delivered at 220 V220\,\text{V} by the transformer. If the current in the primary of the transformer is 2 A2\,\text{A} and its efficiency is 80%80\%, the output current would be:

Show answer

Answer: (c)

Step-by-step solution coming soon.

Report a mistake
Q86COMEDK 2025Medium

AC Generator & Transformer

The ratio of the number of turns of the primary coil to the secondary coil of an ideal transformer is 5:15:1. The primary is connected to 220 V220\,\text{V} supply. What is the output power of the transformer if the output resistance is 11 Ω11\,\Omega ?

Show answer

Answer: (c)

Step-by-step solution coming soon.

Report a mistake
Q87COMEDK 2024Easy

AC Generator & Transformer

A transformer of 100%100\% efficiency has 200200 turns in the primary and 4000040000 turns in the secondary. It is connected to a 220 V220\,\text{V} main supply and secondary feeds to a 100 KΩ100\,\text{K}\Omega resistance. The potential difference per turn is

Show answer

Answer: (d)

Step-by-step solution coming soon.

Report a mistake
Q88COMEDK 2024Medium

AC Generator & Transformer

A transformer has 400400 turns in its primary winding and 800800 turns in its secondary winding. The primary voltage is 20 V20\,\text{V} and the load in the secondary is 4 ohm4\,\text{ohm}. The current in the primary, assuming it to be an ideal transformer, is

Show answer

Answer: (b)

Step-by-step solution coming soon.

Report a mistake
Q89COMEDK 2024Medium

AC Generator & Transformer

A transformer which steps down 330 V330\,\text{V} to 33 V33\,\text{V} is to operate a device having impedance 110 Ω110\,\Omega. The current drawn by the primary coil of the transformer is :

Show answer

Answer: (b)

Step-by-step solution coming soon.

Report a mistake
Q90COMEDK 2023Medium

AC Generator & Transformer

The current drawn by the primary coil of an ideal transformer, which steps up 22 V22\,\text{V} into 220 V220\,\text{V}, to operate a device having a load resistance 110 Ω110\,\Omega is:

Show answer

Answer: (a)

Step-by-step solution coming soon.

Report a mistake
Q91COMEDK 2020Easy

AC Generator & Transformer

In step-up transformer, relation between number of turns in primary (NPN_P) and number of turns in secondary (NSN_S) coils is

Show answer

Answer: (a)

Step-by-step solution coming soon.

Report a mistake
Q92KCET 2026Medium

AC Generator & Transformer

A small town with a demand of 900 kW900\,\text{kW} of electric power at 220 V220\,\text{V} is situated 20 km20\,\text{km} away from an electric power generating station. Each wire of the two-wire transmission line has a resistance per unit length of 5×10−4 Ω m−15\times10^{-4}\,\Omega\,\text{m}^{-1}. The town gets power from the line through a 45000 V45000\,\text{V} to 220 V220\,\text{V} step-down transformer at a substation in the town. The line power loss in the form of heat is:

Show answer

Answer: (b)

Step-by-step solution coming soon.

Report a mistake
Q93KCET 2023Easy

AC Generator & Transformer

An ideal transformer has a turns ratio of 1010. When the primary is connected to 220 V220\,\text{V}, 50 Hz50\,\text{Hz} as source, the power output is

Show answer

Answer: (c)

Step-by-step solution coming soon.

Report a mistake
Q94KCET 2018Easy

AC Generator & Transformer

A step-up transformer operates on a 230 V230\,\text{V} line and a load current of 2 A2\,\text{A}. The ratio of primary and secondary windings is 1:251:25. Then, the current in the primary is

Show answer

Answer: (b)

Step-by-step solution coming soon.

Report a mistake
Q95AP EAPCET 2025Medium

AC Generator & Transformer

An AC source of internal resistance 103 Ω10^3\,\Omega is connected to a transformer. The ratio of the number of turns in the primary to the number of turns in the secondary to match the source to a load resistance of 10 Ω10\,\Omega is

Show answer

Answer: (b)

Step-by-step solution coming soon.

Report a mistake
Q96TS EAMCET 2023Easy

AC Generator & Transformer

In an ideal step up transformer, if the input voltage and input power are V1V_1 and P1P_1 respectively and the output voltage and output power are V2V_2 and P2P_2 respectively, then

Show answer

Answer: (d)

Step-by-step solution coming soon.

Report a mistake
Q97TS EAMCET 2022Medium

AC Generator & Transformer

A generator produces a current of 100 A100\,\text{A} at 4000 V4000\,\text{V}. The voltage is stepped up to 2×105 V2 \times 10^{5}\,\text{V} by a transformer before being sent on a high voltage transmission line of resistance 50 Ω50\,\Omega. The percentage of power loss in the transmission line is

Show answer

Answer: (b)

Step-by-step solution coming soon.

Report a mistake
Q98CBSE Class 12 2021Easy

AC Generator & Transformer

The core of a transformer is laminated to reduce the effect of

Show answer

Answer: (d)

Step-by-step solution coming soon.

Report a mistake
Q99CBSE Class 12 2021Easy

AC Generator & Transformer

Assertion (A) : A step-up transformer cannot be used as a step-down transformer.
Reason (R) : A transformer works only in one direction.

Show answer

Answer: (d)

Step-by-step solution coming soon.

Report a mistake